オックスフォード・インストゥルメンツツの一部
拡張

iDus 416

新発売のAndor社製 iDus 416は、低ダークカレントと超高効率の絶妙の組み合わせが特色で、極めて優れた近赤外線検出感度を示します。取得時間を大幅に短縮するとともに、手間を要する液体窒素冷却の必要性を排除して、ラマン分光、フォトルミネセンス分光に最適な検出器となりました。

  • Low dark current
  • Peak QE up to 95%
  • 30 mm wide sensor
  • TE cooling down to -95ºC
  • 15 µm pixels


お問い合わせ

The unique 2000 x 256, 15 µm pixel array allows extended, broadband and high resolution spectral acquisition, while the fringe suppression technology virtually eliminates the optical etalonning at the higher wavelengths.

With its compact form factor and USB 2.0 connectivity, the iDus 416 can be seamlessly integrated to Shamrock USB 2.0 spectrographs and controlled from a laptop. Andor’s UltraVac™ technology carries a unique track record when it comes to performance and reliability, maintaining superb performance year after year for both Research users and industrial integrators.

Low dark current - 10x better than Back-Illuminated Deep-Depletion NIMO sensors, best SNR in the NIR.

Peak QE up to 95% - Best detection capability in the NIR.

15 µm pixels - Ideal for high resolution spectroscopy.

30 mm wide sensor - Superior simultaneous band-pass capture

Fringe suppression technology as standard - Optical etalonning virtually eliminated.

TE cooling down to -95°C - Critical for elimination of dark current detection limit - no inconvenience associated with LN2

Ultravac™ - Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance year after year.

USB 2.0 connection - Ideal for laptop operation.

Compact and rugged platform - Ideal for OEM integration & laboratory setups.

Solis software for Spectroscopy - Comprehensive, user-friendly interface for simultaneous detector & spectrograph control

Software Development Kit (SDK) - Ease of control integration into complex setups: Matlab, Labview, Visual Basic or C/C++

アップグレード・アクセサリー

XW-RECR - Coolant re-circulator for enhanced cooling performance

ACC-XW-CHIL-160 - Oasis 160 Ultra Compact Chiller Unit (tubing to be ordered separately)

ACC-6MM-TUBING-2xxxxM - 6 mm tubing option for ACC-XW-CHIL-160

LM-C - C-mount lens adaptor

LM-NIKON-F - F-mount lens adaptor

LMS-NIKON-F-NS25B - Nikon F-mount lens adaptor with shutter

ACC-SD-VDM1000 - Shutter Driver for NS25B Bistable Shutter (not needed for Shamrock spectrographs)

ACC-SHT-NS25B - Bistable Shutter, Standalone (not needed for Shamrock spectrographs)

ご興味ございますか?

その他アプリケーション

ナノマテリアルの物性評価不正物質の迅速分析低次元構造の物性評価発光デバイスの製造と評価光学イメージングシステムモジュール式顕微分光法